TR008-96 | 20120425.0 www.vogelzang.com DURANGO™ | Page 7
FLOOR
PROTECTOR
DASHED LINES SHOW HORIZONTAL CHIMNEY CONNECTOR
AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH
AND EXTENDING 2” BEYOND EACH SIDE
COMBUSTIBLE CONSTRUCTION PER NFPA 211
BACKWALL
SIDEWALL
31"
4 8"
16"min.
6"min.17"
22"
min.
25.8"
min.
14"
min.
11"
min.
TOP VIEW
29"
TR008
CAUTION: FAILURE TO FOLLOW THESE
MINIMUM CLEARANCE REQUIRE-
MENTS MAY RESULT IN AN UNSAFE
INSTALLATION AND COULD CAUSE A FIRE.
8. This stove meets U.S. Test Standard:
UL 1482-1996.
9. Always locate stove to provide a source of fresh
air into the room where the unit is installed.
Failure to do so may result in air starvation of other
fuel burning appliances and the possible develop-
ment of hazardous conditions.
NOTE: ANY WALL CONTAINING COMBUSTI-
BLE MATERIAL SUCH AS WOODEN STUDS OR
DRYWALL AND FACED WITH BRICK OR STONE
MUST BE CONSIDERED A COMBUSTIBLE
SURFACE.
6. DO NOT INSTALL THIS STOVE IN A MOBILE
HOME, MANUFACTURED HOME, TRAILER OR
TENT – NO EXCEPTIONS! (HUD FEDERAL
STANDARD: 24 CFR CH.XX)
7. The clearances provided are minimum
dimensions determined by OMNI-Test Lab-
oratories, Inc., the manufacturer’s testing
laboratory. Installation of this stove must
comply with the latest edition of NFPA 211 for
reduced clearances and/or your local build-
ing code rulings. Use whichever minimum
dimensions are LARGEST.
Fig. 5 – Top View Minimum Clearance Dimensions from
Combustible Surfaces
13"
19"
19"
13"
CORNER CLEARANCES
Fig. 6 – Minimum Corner Clearance
Dimension from Combustible Surfaces
Fig. 7 – Front & Side Views: Minimum Clearance Dimensions
from Combustible Surfaces
CAUTION: KEEP FURNISHINGS AND
OTHER COMBUSTIBLE MATERIALS
AWAY FORM THE STOVE AND OUTSIDE
MINIMUM CLEARANCES.